Heat pump RS82WA
thermal power 10 of the kW (phote
1), the conscription of the 2.75kW electricity, the productivity of 240
l/h, the compressor the Toshiba, the Japanese technology, dimensions
700X430X1010, the weight of 100 kg.
Reliable and ecological heat pump pantherma
of type air/water, which lets not only heat the
building (the demand for the 10kw central heating, the annual cost of
heating ok 2.5 tys), but also to prepare warm functional water.
Heat pump RS15R
thermal power 44 of the kW (phote
2), conscription of the electricity 11.4 kW, the productivity of 1100
l/h, the compressor the Toshiba, the Japanese technology, dimensions
1420
X725X1365, the weight of 360 kg.
Modern heating system fully automatic, not
requiring no conservation and the supervision. 36 months of the
guarantee, the service.


The effectiveness of
the pump of the warmth fluctuates within from 3.5 to 5.0. He is marking
it, that behind 1kW of the electric energy put to the drive of the pump
of the warmth we are getting from 3.5 up to 5 kW of the thermal energy.
All traditional heating systems have the effectiveness below 1.0. They
in this way are getting ž of heating energy free of charge. The rest
part of the payment is being incurred behind the electric energy needed
for the drive of engines.
Cost of 1m3
heating waters from 15°C to 55°C
|
Name
sources of the warm weather |
Productivity |
Total cost in PLN |
|
Electricity |
95% |
16,66 |
|
Fuel oil |
85% |
11,32 |
|
LPG |
70% |
10,07 |
|
Natural gas |
70% |
8,68 |
|
Coal |
64% |
6,81 |
|
Heat pump |
350% |
4,52 |
pick the
technical information up in the pdf file
1. Vacuum interceptor
2. Group of protections
3. Driver
4. Exchanger
1.Vacuum
interceptor
these are devices being good for acquiring the energy
from the sun. He is built from the set of vacuum pipes, the casing and
elements being a heat conductor. (205cm x of 85 cm)
"
Heat pipe " is
being assembled inside the vacuum pipe including the tin radiator, of
which increasing the receipt of the warmth is a task from
of absorber.
In the internal
space " heat pipe " liquid is about boiling
point 25 about C. liquid is
starting Powyżej of this temperature to boil, steam is going up till the
upper end " heat pipe " where by giving back
the central heating to the sailing medium is undergoing liquefying and
down this Process is flowing down – is running cyclically.
  
Temperature
initial perhaps to achieve even to 250
about C on the finish.
This technology
provides with the higher effectiveness into the cloudy weather and in
the winter.

pick
the technical information up in the pdf file
|